Dual Block Thermal Cyclers TCM-4040D
Availability : 2 - 3 weeks
Description Key Features Technical Downloads
Dual Block Thermal Cyclers TCM-4040D has been used in PCR applications in research and development, food science, pharmaceuticals, life science, animal diagnostics, and analytical laboratories. Features with customized Marlow Peltier heating units and form 4 circuits to control 4 temperature zones with vibrant touch LCD display and maximum ramping rate 5 ?/s.
Dual Block Thermal Cyclers TCM-4040D accommodates 48×0.2 ml + 30×0.5 ml, and In-situ plate, this block is completely independently of each other and without interference Fabricated with anodizing technology that have prompts heating conducting and adequate corrosion resistance property.
Mores Information
number_of_cycle
100
gradient_temp_range
30 to 100?
power
-
resolution
? � 0.1?
temperature_range
0 to 100?
capacity
48�0.2 ml + 30�0.5 ml
model
TCM-4040D
Model
TCM-4005D
TCM-4010D
TCM-4015D
TCM-4020D
TCM-4025D
TCM-4030D
TCM-4035D
TCM-4040D
TCM-4045D
TCM-4050D
Capacity
96×0.2 ml
60×0.5 ml
2×48×0.2 ml
48×0.2 ml + 30×0.5 ml
384 well, In-situ Plate
Display
LCD, 8 inch, 800×600 pixels
Temperature Range
0 to 100?
Number of Program
10000 +(USB FLASH)
Uniformity
≤ ± 0.2?
Accuracy
≤ ± 0.1?
Resolution
0.1?
Number of Cycle
100
Number of Step
30
Holding Temperature
4?
Temperature Control
Block\Tube
Heating Rate
5?/s
Cooling Rate
4?/s
Ramping Rate Adjustable
0.1 to 5?
Gradient Temp. Range
-
30 to 100?
-
30 to 100?
-
30 to 100?
-
30 to 100?
-
30 to 100?
Gradient Uniformity
-
≤±0.2?
-
≤±0.2?
-
≤±0.2?
-
≤±0.2?
-
≤±0.2?
Gradient Accuracy
-
≤±0.2?
-
≤±0.2?
-
≤±0.2?
-
≤±0.2?
-
≤±0.2?
Gradient Spread
-
1 to 30?
-
1 to 30?
-
1 to 30?
-
1 to 30?
-
1 to 30?
Hot Lid Height Adjustable
Step less Adjustable
Hot Lid Temperature
30 to 110?
Connectivity
USB 2.0, LAN
Temp Increment/Decrement
0.1 to 10.0?
Increase/Decrease in Time
1 Sec to 600 Sec
Power consumption
600 W
Overall Dimensions
390×270×255 mm
Net Weight
9 kg
Electrical Requirements
264 V AC , 47 to 63 Hz
Catalogue No.
620300503
620301003
620301503
620302003
620302503
620303003
620303503
620304003
620304503
620305003
Model
TCM-4005D
TCM-4010D
TCM-4015D
TCM-4020D
TCM-4025D
TCM-4030D
TCM-4035D
TCM-4040D
TCM-4045D
TCM-4050D
Capacity
96×0.2 ml
60×0.5 ml
2×48×0.2 ml
48×0.2 ml + 30×0.5 ml
384 well, In-situ Plate
Display
LCD, 8 inch, 800×600 pixels
Temperature Range
0 to 100?
Number of Program
10000 +(USB FLASH)
Uniformity
≤ ± 0.2?
Accuracy
≤ ± 0.1?
Resolution
0.1?
Number of Cycle
100
Number of Step
30
Holding Temperature
4?
Temperature Control
Block\Tube
Heating Rate
5?/s
Cooling Rate
4?/s
Ramping Rate Adjustable
0.1 to 5?
Gradient Temp. Range
-
30 to 100?
-
30 to 100?
-
30 to 100?
-
30 to 100?
-
30 to 100?
Gradient Uniformity
-
≤±0.2?
-
≤±0.2?
-
≤±0.2?
-
≤±0.2?
-
≤±0.2?
Gradient Accuracy
-
≤±0.2?
-
≤±0.2?
-
≤±0.2?
-
≤±0.2?
-
≤±0.2?
Gradient Spread
-
1 to 30?
-
1 to 30?
-
1 to 30?
-
1 to 30?
-
1 to 30?
Hot Lid Height Adjustable
Step less Adjustable
Hot Lid Temperature
30 to 110?
Connectivity
USB 2.0, LAN
Temp Increment/Decrement
0.1 to 10.0?
Increase/Decrease in Time
1 Sec to 600 Sec
Power consumption
600 W
Overall Dimensions
390×270×255 mm
Net Weight
9 kg
Electrical Requirements
264 V AC , 47 to 63 Hz
Catalogue No.
620300503
620301003
620301503
620302003
620302503
620303003
620303503
620304003
620304503
620305003