Real-Time PCR System 6 Channel
Real-Time PCR System 6 Channel

Real-Time PCR System 6 Channel

Real-Time PCR System 6 Channel ITR-6000 has been used in immunology, HGP, forensic medicine, oncology, histology, population biology, paleobiologic, zoology, botany and clinical diagnosis of viruses, tumours and hereditary disorder. Designed with 3×48×0.2 ml (5 to 100 µl) capacity and 10to 1010 test dynamic range. Rapidly set up runs and monitor amplification traces in real time on integrated LCD touch screen. Freshly designed automatic hot-lid without manual operation ensures constant pressure for various tube heights.

Description
Specification
Technical

Real-Time PCR System 6 Channel ITR-6000 has been used in immunology, HGP, forensic medicine, oncology, histology, population biology, paleobiologic, zoology, botany and clinical diagnosis of viruses, tumours and hereditary disorder. Designed with 3×48×0.2 ml (5 to 100 µl) capacity and 10to 1010 test dynamic range. Rapidly set up runs and monitor amplification traces in real time on integrated LCD touch screen. Freshly designed automatic hot-lid without manual operation ensures constant pressure for various tube heights.

  • The system composed of Real-time sample with 3 independent detection system thermal cycler
  • Achieve accurate results with volumes of up to 5 to 100 µl
  • Highly cost effective 8 channels along with fluorescent dyes
  • Buildings with photoelectric sensor detector and LED display
  • Real time remote control come with wireless facilities
  • Real time fluorescence quantitative PCR technology
  • Productions with quick laboratory pollution detection and positive detection rate
  • Programming interface including quantitative analysis, sample parameter setting, melting curve, gradient amplification curve, sensitivity experiment
  • Outstanding performance of thermal plate
  • Design the system for appropriate requirements
  • Working based on to achieve reagent sample amplification, denaturation of sample under high temperature, annealing and extension under low or optimum temperature
  • With up to 144 samples detection , supreme thermal cycler performance, incomparable stand-alone functionality and dominant however software are easy to use
  • USB 2.0 cable and Windows vista/7/8/10 operating system

Model

ITR-6000

Capacity

3×48×0.2 ml(5 to 100 µl):48, 96 and 144(optional)

Reaction Volume

5 to 100 µl

Display

LED

Temperature Range

4 to 100°C

Uniformity

±0.1°C

Temperature Control

±0.1°c

Detector

Photoelectric sensor

Sensitivity

1 copy

Test Dynamic Range

100 to 1010

Fluorescent Dye

F1: FAM, SYBR, GREEN, F2: VIC, HEX, JOE, TET, YELLOW, F3: CY3, F4: ROX, F5: CY5, F6:, CY5.5, F7: Reserved , F8: Reserved

Channel

8

Ramp up   Rate

≥ 6.5°C/s

Ramp down Rate

≥ 6.5°C/s

Hot Lid

Automatic

Hot Lid Temperature

30 to 110°C

Sample Linearity

Linear regression coefficient r≥0.999

Fluorescent Intensity Detection

CV≤0.5%

Temperature Control Pattern

Semi-conductor TE module

Operating System

Windows vista/7/8/10

Connectivity

USB 2.0

Overall Dimensions

586×525×780 mm

Weight

 

Electrical Requirements

100 to 240V, 50/60Hz, 500 to 1500 VA

Catalogue No.

6007005-01

6007005-02

Model

ITR-6000

Capacity

3×48×0.2 ml(5 to 100 µl):48, 96 and 144(optional)

Reaction Volume

5 to 100 µl

Display

LED

Temperature Range

4 to 100°C

Uniformity

±0.1°C

Temperature Control

±0.1°c

Detector

Photoelectric sensor

Sensitivity

1 copy

Test Dynamic Range

100 to 1010

Fluorescent Dye

F1: FAM, SYBR, GREEN, F2: VIC, HEX, JOE, TET, YELLOW, F3: CY3, F4: ROX, F5: CY5, F6:, CY5.5, F7: Reserved , F8: Reserved

Channel

8

Ramp up   Rate

≥ 6.5°C/s

Ramp down Rate

≥ 6.5°C/s

Hot Lid

Automatic

Hot Lid Temperature

30 to 110°C

Sample Linearity

Linear regression coefficient r≥0.999

Fluorescent Intensity Detection

CV≤0.5%

Temperature Control Pattern

Semi-conductor TE module

Operating System

Windows vista/7/8/10

Connectivity

USB 2.0

Overall Dimensions

586×525×780 mm

Weight

 

Electrical Requirements

100 to 240V, 50/60Hz, 500 to 1500 VA

Catalogue No.

6007005-01

6007005-02