UV Trans-illuminator UT-2000 Series

UV Trans-illuminator UT-2000 Series

UV Transilluminator IUT-2000 Series dual-wavelength UV Trans-illuminator wavelength ranging from 302 nm to 365 nm and detect nucleic acid stained gel to a UV light source using ethidium bromide and other dyes like SYBR-Green and SYPRO- Orange that is mostly used as a nontoxic dye for the post nucleic acid stain. These series have the greatest detection sensitivity for DNA and RNA fragments. This is the most widely used Trans-illuminator used in university, research department, and corporation involved in molecular biology, molecular genetics, medical and sanitation, agriculture, and other life science fields. We also of

Description
Specification
Technical

UV Transilluminator IUT-2000 Series dual-wavelength UV Trans-illuminator wavelength ranging from 302 nm to 365 nm and detect nucleic acid stained gel to a UV light source using ethidium bromide and other dyes like SYBR-Green and SYPRO- Orange that is mostly used as a nontoxic dye for the post nucleic acid stain. These series have the greatest detection sensitivity for DNA and RNA fragments. This is the most widely used Trans-illuminator used in university, research department, and corporation involved in molecular biology, molecular genetics, medical and sanitation, agriculture, and other life science fields. We also offer e a range of electrophoresis products designed with maximum value. We are dedicated to understanding customer needs. Provide high-grade glass for low background. The UV Trans-illuminator includes a UV protection lid that is fascinatingly held in place; adjust it in an angled point and to use it as a protection guard when working on a UV-fluorescent gel.

  • Long life and strong illumination with multiple pieces of LED light
  • CE and FCC certified
  • High-quality UV Trans-illuminators are designed for observing DNA/RNA in agarose gels stained with ethidium bromide dye
  • Features with dual-wavelength options for added flexibility and convenience:302 & 365 nm
  • Equipped with wavelength-selectable that fit for different DNA dyes including SYBR-green, SYPRO-orange
  • Dual-light Trans-illuminator unit system
  • Unique cooling fan features
  • High efficiency of wavelength confirms extremely detective sensitivity, enhance capturing ability for weak signals
  • Design with rational structure and high-quality UV lamp
  • Excellent irradiance uniformity and Unsurpassed UV intensity
  • High-efficiency reflector
  • Adjustable UV protective glass ensuring better UV protection to the user
  • White light filter surface designed for coomassie blue stained protein gels, methylene blue-stained DNA gels, silver-stained protein gels, autoradiographic and microtiter plates
  • Equipped with removable, adjustable UV blocking shield

 

Model

   IUT-2000                                     

         IUT-2100                              

          IUT-2200                             

            IUT-2300                             

            IUT-2400                             

Wavelength

302 nm

302 nm

302 & 365 nm

302 nm

302 & 365 nm

Filter Size

8x15 cm(UltraSafe UV blocking)

16 x 20 cm(UltraSafe UV blocking)

21 x 26 cm (UltraSafe UV blocking)

Design Type

 

Mono wave length

Dual wave length

Mono wave length

Dual wave length

Intensity

 

Adjustable Intensity

UV Lamp

6 W 1 pc

8 W 5 pcs

8 W 9 pcs

8 W 6 pcs

8 W 11 pcs

Sensitivity

0.5 ng

0.1 ng

Certification

CE and FCC

Cover Material

Aluminum alloy metal frame

Dimension

247x132x48.5 mm

280 x 340 x 80 mm

Weight

1.4 kg

4.3 kg

Electrical Requirement

DC 12V, 1.5 A

AC 100V/50Hz

AC 240 v/60 Hz

AC 100V/50Hz

AC 240 v/60 Hz

AC 100V/50Hz

AC 240 v/60 Hz

AC 100V/50Hz

AC 240 v/60 Hz

Catalogue No.

3401005-04

340101001

340101002

340101501

340101502

340102001

340102002

340102501

340102501

Model

   IUT-2000                                     

         IUT-2100                              

          IUT-2200                             

            IUT-2300                             

            IUT-2400                             

Wavelength

302 nm

302 nm

302 & 365 nm

302 nm

302 & 365 nm

Filter Size

8x15 cm(UltraSafe UV blocking)

16 x 20 cm(UltraSafe UV blocking)

21 x 26 cm (UltraSafe UV blocking)

Design Type

 

Mono wave length

Dual wave length

Mono wave length

Dual wave length

Intensity

 

Adjustable Intensity

UV Lamp

6 W 1 pc

8 W 5 pcs

8 W 9 pcs

8 W 6 pcs

8 W 11 pcs

Sensitivity

0.5 ng

0.1 ng

Certification

CE and FCC

Cover Material

Aluminum alloy metal frame

Dimension

247x132x48.5 mm

280 x 340 x 80 mm

Weight

1.4 kg

4.3 kg

Electrical Requirement

DC 12V, 1.5 A

AC 100V/50Hz

AC 240 v/60 Hz

AC 100V/50Hz

AC 240 v/60 Hz

AC 100V/50Hz

AC 240 v/60 Hz

AC 100V/50Hz

AC 240 v/60 Hz

Catalogue No.

3401005-04

340101001

340101002

340101501

340101502

340102001

340102002

340102501

340102501

Image Product Detail Price (Exc. VAT)
UV Trans-illuminator UT-2300

#bls_340102002

UV Trans-illuminator UT-2300
UV Trans-illuminator UT-2300 UV Trans-illuminator wavelength ranging from 302 nm to 365 nm and detect nucleic acid stained gel to a UV light source using ethidium bromide and other dyes like SYBR-Green and SYPRO- Orange that is mostly used as a nonto
2 - 3 weeks Delivery.
$1,520.00
UV Trans-illuminator UT-2300

#bls_340102001

UV Trans-illuminator UT-2300
UV Trans-illuminator UT-2300 UV Trans-illuminator wavelength ranging from 302 nm to 365 nm and detect nucleic acid stained gel to a UV light source using ethidium bromide and other dyes like SYBR-Green and SYPRO- Orange that is mostly used as a nonto
2 - 3 weeks Delivery.
$1,520.00
UV Trans-illuminator UT-2100

#bls_340101002

UV Trans-illuminator UT-2100
UV Trans-illuminator UT-2100 UV Trans-illuminator wavelength ranging from 302 nm to 365 nm and detect nucleic acid stained gel to a UV light source using ethidium bromide and other dyes like SYBR-Green and SYPRO- Orange that is mostly used as a nonto
2 - 3 weeks Delivery.
$1,370.00
UV Trans-illuminator UT-2100

#bls_340101001

UV Trans-illuminator UT-2100
UV Trans-illuminator UT-2100 UV Trans-illuminator wavelength ranging from 302 nm to 365 nm and detect nucleic acid stained gel to a UV light source using ethidium bromide and other dyes like SYBR-Green and SYPRO- Orange that is mostly used as a nonto
2 - 3 weeks Delivery.
$1,370.00