Real-Time PCR System 4 Channel
Real-Time PCR System 4 Channel

Real-Time PCR System 4 Channel

The Iris ITR-4000 real time PCR is applicable to molecular biology, microbiology, medicine, molecular cloning in genetics, sequence analysis and various fields. It conducts the whole process of DNA amplification and PCR products analysis in an enclosed tube. Through PC control, it realizes real time as well as auto analysis. 

Description
Specification
Technical

The Iris ITR-4000 real time PCR is applicable to molecular biology, microbiology, medicine, molecular cloning in genetics, sequence analysis and various fields. It conducts the whole process of DNA amplification and PCR products analysis in an enclosed tube. Through PC control, it realizes real time as well as auto analysis. 

  • Good practicability

  • Wide detection scopes  

  • High sensitivity and accuracy

  • Quantitative analysis

  • Real-time data monitoring

  • Real-time analysis display of the melting curves

  • Automatic assessment of negative or positive results

Model

ITR-4000

Sample Capacity

48×0.2ml

Test Dynamic Range

10-1010

Full plate fluorescence detection time

<3s

Applicable fluorophores

 

F1:FAM, SYBR Green

F2:HEX, VIC, JOE

Temperature Range

30.0-99.9 °C

Temperature Uniformity

±0.3 °C(@55 °C)

Temperature Accuracy

±0.1°C(@55°C)

Heating Rate (MAX)

4°C/s

Cooling Rate (MAX)

4°C/s

Average Heating Rate

≥1.8°C/s

Average Cooling Rate

≥1.8°C/s

Hot-lid Temp. Range

30-105°C

Fluorescence Repeatability

CV≤3%

Sample Detection Repeatability

CV≤3%

Sample Linearity

r ≥0.98

Fluorescence Linearity

r ≥0.99

Communication Interface

USB 2.0/RS-232

Operation System

Windows XP / Vista / 7

Dimension

457×420×335mm

Electrical Requirement

 

Catalogue No.

6006005-00 

Model

ITR-4000

Sample Capacity

48×0.2ml

Test Dynamic Range

10-1010

Full plate fluorescence detection time

<3s

Applicable fluorophores

 

F1:FAM, SYBR Green

F2:HEX, VIC, JOE

Temperature Range

30.0-99.9 °C

Temperature Uniformity

±0.3 °C(@55 °C)

Temperature Accuracy

±0.1°C(@55°C)

Heating Rate (MAX)

4°C/s

Cooling Rate (MAX)

4°C/s

Average Heating Rate

≥1.8°C/s

Average Cooling Rate

≥1.8°C/s

Hot-lid Temp. Range

30-105°C

Fluorescence Repeatability

CV≤3%

Sample Detection Repeatability

CV≤3%

Sample Linearity

r ≥0.98

Fluorescence Linearity

r ≥0.99

Communication Interface

USB 2.0/RS-232

Operation System

Windows XP / Vista / 7

Dimension

457×420×335mm

Electrical Requirement

 

Catalogue No.

6006005-00 

We can't find products matching the selection.