Compact Conductivity Meter ICM-300 Series design to meet the most demanding and robust compliance requirements. Can measure different parameters; TDS, conductivity, DO, pH or pX, temperature, salinity, ORP automatic temperature. Designed to increase productivity in the lab and in the field. Build-in sensors that are automatically identified by the instrument. The automatic temperature compensation delivers accurate reading over the entire range and manual temperature calibration to correct temperature deviation. CE Certified.
Description
Specification
Technical
Compact Conductivity Meter ICM-300 Series design to meet the most demanding and robust compliance requirements. Can measure different parameters; TDS, conductivity, DO, pH or pX, temperature, salinity, ORP automatic temperature. Designed to increase productivity in the lab and in the field. Build-in sensors that are automatically identified by the instrument. The automatic temperature compensation delivers accurate reading over the entire range and manual temperature calibration to correct temperature deviation. CE Certified.
Conductivity / TDS / Salinity / Resistivity Mode: 6 point conductivity meter calibration with automatic temperature compensation ranging COND:0.0 to 100.0℃; salinity: 0 to 50 g/L. Support selectable ion such as H+,Ag+,Na+,K+,Cl-,F etc. Standard configuration including platinum black conductivity electrode, DO probe and standard buffer.
pH Mode: High accuracy portable multiparameter water quality meter is equipped with a large backlit LCD display. 1 to 5 points pH calibration with auto-buffer recognition with automatic temperature compensation ranging from pH: 0.0 to 100.0℃ Standard configuration including pH combination electrode. Selectable automatic identification of 25 kinds of buffer solutions, including DIN and NIST. The automatic electrode slope display helps the user decide whether to replace the sensor.
DO Mode: With automatic temperature compensation ranging from 0.0 to 40.0℃. Air-saturated water and zero oxygen solution.
Features
Functional measuring parameters including conductivity, resistivity, total dissolved solid (TDS), salinity, and temperature
Simple calibration up to 6 point calibration with automatic
Large, well-structured 7-inch touch screen and LCD display with navigation
CE Certified
Available in both portable and benchtop model
Automatic and manual temperature compensation
Maximum storage: 2200 set
Platinum black conductivity electrode; pH combination electrode, DO probe; standard buffer as standard configuration
Compiled with USB and RS232 to connect with PC and Printer
Universal power adaptor and 4 AA batteries
Accessories
Platinum Black Conductivity Electrode
pH Combination Electrode
DO Probe
Standard Buffer
Model
ICM-305
ICM-310
Parameter
Conductivity/DO/pH/pX/Temperature
Concentration/Saturation/℃
Display
LCD
7 inch touch screen
pH/pX Range
-2 to 20
-
pH/pX Resolution
0.01
-
pH/pX Accuracy
pH: ±0.01
-
Conductivity Range
0 μs/cm to 199.9 mS/cm
-
Conductivity Resolution
0.001 μs/cm
-
Conductivity Accuracy
±1.0% FS
-
Resistivity Range
0.00 Ω.cm to 20.00 MΩ.cm
-
Resistivity Resolution
0.01 Ω.cm
-
Resistivity Accuracy
±1.0% FS
-
Temperature Range
-5 to 105℃
-5 to 130℃
Temperature Resolution
0.1℃
0.1℃
Temperature Accuracy
±0.3℃
±0.1%
TDS Range
0.000 mg/L to 100 g/L
-
TDS Resolution
0.001 mg/L
-
Salinity Range
0 to 8 %
-
Salinity Resolution
0.01%
-
Salinity Accuracy
±0.2%
-
DO Range
0 to 19.99 mg/L
0 to 90 mg/L
DO Resolution
0.01 mg/L
0.01 mg/L
DO Accuracy
±0.30 mg/L
±0.10 mg/L
DO Saturation/Concentration Range
0 to 199.9 %
0 to 600 %
DO Saturation/Concentration Resolution
0.10%
0.10%
DO Saturation/ Concentration Accuracy
±10.0%
±2.0%
Ion Concentration Range
0 to 19990 ug/L,mg/L,g/L,mol/L,mmol/L
-
Salinity Compensation
-
0 to 50 g/L
Temperature Compensation
Auto, pH: 0.0 to 100.0℃ ; COND: 0.0 to 100.0℃ ; DO: 0.0 to 40.0℃
-
Calibration
Offset and Full Scale
6 points p H and 5 points conductivity calibration
Ion Mode
H+,Ag+,Na+,K+,Cl-,F
-
Standard Configuration
Platinum Black Conductivity Electrode; pH Combination Electrode, DO Probe; Standard Buffer
-
Storage
200 sets
1000 data
Interface
RS232
RS232 and USB
Dimensions
250x195x100mm
280x280x130mm
Weight
1 kg
2.5 kg
Electrical Requirement
Universal power adaptor DC 9V/800mA
Universal power adaptor DC 24V/3A
Catalogue No.
7101045-04
7101050-04
Model
ICM-305
ICM-310
Parameter
Conductivity/DO/pH/pX/Temperature
Concentration/Saturation/℃
Display
LCD
7 inch touch screen
pH/pX Range
-2 to 20
-
pH/pX Resolution
0.01
-
pH/pX Accuracy
pH: ±0.01
-
Conductivity Range
0 μs/cm to 199.9 mS/cm
-
Conductivity Resolution
0.001 μs/cm
-
Conductivity Accuracy
±1.0% FS
-
Resistivity Range
0.00 Ω.cm to 20.00 MΩ.cm
-
Resistivity Resolution
0.01 Ω.cm
-
Resistivity Accuracy
±1.0% FS
-
Temperature Range
-5 to 105℃
-5 to 130℃
Temperature Resolution
0.1℃
0.1℃
Temperature Accuracy
±0.3℃
±0.1%
TDS Range
0.000 mg/L to 100 g/L
-
TDS Resolution
0.001 mg/L
-
Salinity Range
0 to 8 %
-
Salinity Resolution
0.01%
-
Salinity Accuracy
±0.2%
-
DO Range
0 to 19.99 mg/L
0 to 90 mg/L
DO Resolution
0.01 mg/L
0.01 mg/L
DO Accuracy
±0.30 mg/L
±0.10 mg/L
DO Saturation/Concentration Range
0 to 199.9 %
0 to 600 %
DO Saturation/Concentration Resolution
0.10%
0.10%
DO Saturation/ Concentration Accuracy
±10.0%
±2.0%
Ion Concentration Range
0 to 19990 ug/L,mg/L,g/L,mol/L,mmol/L
-
Salinity Compensation
-
0 to 50 g/L
Temperature Compensation
Auto, pH: 0.0 to 100.0℃ ; COND: 0.0 to 100.0℃ ; DO: 0.0 to 40.0℃
-
Calibration
Offset and Full Scale
6 points p H and 5 points conductivity calibration
Ion Mode
H+,Ag+,Na+,K+,Cl-,F
-
Standard Configuration
Platinum Black Conductivity Electrode; pH Combination Electrode, DO Probe; Standard Buffer
Compact Conductivity Meter CM-310 design to meet the most demanding and robust compliance requirements. Can measure different parameters; TDS, conductivity, DO, pH or pX, temperature, salinity, ORP automatic temperature.
Designed to increase p
Compact Conductivity Meter CM-305 design to meet the most demanding and robust compliance requirements. Can measure different parameters; TDS, conductivity, DO, pH or pX, temperature, salinity, ORP automatic temperature.
Designed to increase p