Portable Conductivity Meter ICM-200 Series provides the ideal solution for measuring TDS, DO, pH, pX, temperature, Salinity, DO Saturation all these parameters. The Conductivity meter is best for observing different applications such as the number of salts or dissolved solids in water. The readings are mechanically temperature compensated with the range of -5 to 135℃, delivers accurate reading over the entire range and manual temperature calibration to correct temperature deviation. CE Certified. Designed to increase productivity in the lab and in the field.
Description
Specification
Technical
Portable Conductivity Meter ICM-200 Series provides the ideal solution for measuring TDS, DO, pH, pX, temperature, Salinity, DO Saturation all these parameters. The Conductivity meter is best for observing different applications such as the number of salts or dissolved solids in water. The readings are mechanically temperature compensated with the range of -5 to 135℃, delivers accurate reading over the entire range and manual temperature calibration to correct temperature deviation. CE Certified. Designed to increase productivity in the lab and in the field.
Conductivity / TDS / Salinity / Resistivity Mode: 6 point conductivity meter calibration with automatic temperature compensation ranging COND:0.0 to 100.0℃; salinity: 0 to 50 g/L. Support selectable ion such as H+,Ag+,Na+,K+,Cl-,F etc. Standard configuration including platinum black conductivity electrode, DO probe and standard buffer.
pH Mode: High accuracy portable multiparameter water quality meter is equipped with a large backlit LCD display. 1 to 5 points pH calibration with auto-buffer recognition with automatic temperature compensation ranging from pH: 0.0 to 100.0℃ Standard configuration including pH combination electrode. Selectable automatic identification of 25 kinds of buffer solutions, including DIN and NIST. The automatic electrode slope display helps users decide whether to replace the sensor.
DO Mode: With automatic temperature compensation ranging from 0.0 to 40.0℃. Air-saturated water and zero oxygen solution.
Features
Functional measuring parameters including conductivity, dissolve oxygen, pH, pX, and temperature
Simple calibration 0 offset and Full scale
Large, well-structured 7-inch touch screen and LCD display with navigation
CE Certified
Available in a portable model
Automatic and manual temperature compensation
Maximum storage: 2200 set
Platinum black conductivity electrode; pH combination electrode, DO probe; standard buffer as standard configuration
Compiled with USB and RS232 to connect with PC and Printer
Li-on Battery
Accessories
Platinum Black Conductivity Electrode;
pH Combination Electrode;
DO Probe (waterproof);
Standard Buffer
Model
ICM-205
ICM-210
ICM-215
ICM-220
Parameter
Cond/ DO/pH/pX/℃/TDS/Salinity/DO Saturation
Display
TFT Touch screen
Backlit LCD
pH/pX Range
-2 to 19.999
-
pH/pX Resolution
0.001
-
pH/pX Accuracy
±0.002
-
Conductivity Range
0 μs/cm to 199.9 mS/cm
-
0 μs/cm to 199.9 mS/cm
Conductivity Resolution
-
Conductivity Accuracy
±0.5% FS
-
±0.5% FS
Resistivity Range
0 Ω·cm to 20 MΩ·cm
-
0 Ω·cm to 20 MΩ·cm
Resistivity Resolution
-
Resistivity Accuracy
±0.5% FS
-
±0.5% FS
Temperature Range
-5 to 135℃
Temperature Resolution
0.1℃
Temperature Accuracy
±0.3℃
TDS Range
0 mg/L to 100 g/L
-
0 mg/L to 100 g/L
Salinity Range
0 to 8 %
-
0 to 8 %
Salinity Accuracy
±0.1 %
-
±0.1 %
DO Range
0 to 99.99 mg/L
-
0 to 99.99 mg/L
DO Resolution
0.01 mg/L
-
0.01 mg/L
DO Accuracy
±0.30 mg/L
-
±0.30 mg/L
DO Saturation/Concentration Range
0 to 199.9 %
-
0 to 199.9 %
DO Saturation/Concentration Resolution
0.01 mg/L
-
0.01 mg/L
DO Saturation/ Concentration Accuracy
0.10%
-
0.10%
Ion Concentration Range
0 to 19990 ug/L,mg/L,g/L,mol/L,mmol/L
-
Temperature Compensation
Auto, pH: 0.0 to 100.0℃; COND: 0.0 to 100.0℃; DO: 0.0 to 40.0℃
Calibration
0- Offset and Full Scale
-
-
0 Offset and Full Scale
Ion Mode
H+,Ag+,Na+,K+,Cl-,F
-
Measuring Mode
3 mode
Certification
CE
Storage
2200 sets
Interface
USB
Electrical Requirement
Li-on Battery , 1.1DC
Catalogue No.
7101025-04
7101030-04
7101035-04
7101040-04
Model
ICM-205
ICM-210
ICM-215
ICM-220
Parameter
Cond/ DO/pH/pX/℃/TDS/Salinity/DO Saturation
Display
TFT Touch screen
Backlit LCD
pH/pX Range
-2 to 19.999
-
pH/pX Resolution
0.001
-
pH/pX Accuracy
±0.002
-
Conductivity Range
0 μs/cm to 199.9 mS/cm
-
0 μs/cm to 199.9 mS/cm
Conductivity Resolution
-
Conductivity Accuracy
±0.5% FS
-
±0.5% FS
Resistivity Range
0 Ω·cm to 20 MΩ·cm
-
0 Ω·cm to 20 MΩ·cm
Resistivity Resolution
-
Resistivity Accuracy
±0.5% FS
-
±0.5% FS
Temperature Range
-5 to 135℃
Temperature Resolution
0.1℃
Temperature Accuracy
±0.3℃
TDS Range
0 mg/L to 100 g/L
-
0 mg/L to 100 g/L
Salinity Range
0 to 8 %
-
0 to 8 %
Salinity Accuracy
±0.1 %
-
±0.1 %
DO Range
0 to 99.99 mg/L
-
0 to 99.99 mg/L
DO Resolution
0.01 mg/L
-
0.01 mg/L
DO Accuracy
±0.30 mg/L
-
±0.30 mg/L
DO Saturation/Concentration Range
0 to 199.9 %
-
0 to 199.9 %
DO Saturation/Concentration Resolution
0.01 mg/L
-
0.01 mg/L
DO Saturation/ Concentration Accuracy
0.10%
-
0.10%
Ion Concentration Range
0 to 19990 ug/L,mg/L,g/L,mol/L,mmol/L
-
Temperature Compensation
Auto, pH: 0.0 to 100.0℃; COND: 0.0 to 100.0℃; DO: 0.0 to 40.0℃
Portable Conductivity Meter CM-220 provides the ideal solution for measuring TDS, DO, pH, pX, temperature, Salinity, DO Saturation all these parameters. The Conductivity meter is best for observing different applications such as the number of s
Portable Conductivity Meter CM-215 provides the ideal solution for measuring TDS, DO, pH, pX, temperature, Salinity, DO Saturation all these parameters. The Conductivity meter is best for observing different applications such as the number of s
Portable Conductivity Meter CM-210 provides the ideal solution for measuring TDS, DO, pH, pX, temperature, Salinity, DO Saturation all these parameters. The Conductivity meter is best for observing different applications such as the number of s
Portable Conductivity Meter CM-205 provides the ideal solution for measuring TDS, DO, pH, pX, temperature, Salinity, DO Saturation all these parameters. The Conductivity meter is best for observing different applications such as the number of s